How do I reset my s&g 6120 safe lock?

Use the Management Reset Code to Reset my S&G 6120 Lock?

The Sargent and Greenleaf Management Reset code (MRC) is a 7 digit code. The 2 numbers in the MRC that are separated by a “/” or are in “[]” have to be entered simultaneously – press both numbers at the same time.

Execute the MRC sequence using the following steps:
1. Press * 6 #
2. Now enter the MRC
3. After entering the MRC, press #

You will hear 1 beep for each time the MRC has been executed. (If this is the first time that the MRC has been executed, you will hear only 1 beep.)

EX: *6# 135 0/1 87 #

The Master Code has now been reset to the Factory Default of 123456#
Enter the Master Code 123456#, and the lock will open.

This reset code is applicable to the following locks:
S&G 6120, 6123, Z02 Locks

Click here to download/print the Sargent & Greenleaf 6120 lock reset code instruction

Sargent and Greenleaf 6120 Electronic Safe Lock – Overview

Sargent and Greenleaf 6120 electronic safe locks combine proven functionality with a wide range of options that balance convenience and control. Easy to install or retrofit, S&G’s Model 6120 electronic safe lock simplifies security upgrades for your safe. Model 6120 is EMP-resistant, and is perfect for commercial safes or home gun safes.

S&G’s electronic safe locks are motor-driven and offer one-step operation for convenient use and easy management.

Sargent and Greenleaf 6120 Electronic Safe Lock Keypad Sargent and Greenleaf Electronic Safe Lock Kepad Picture Sargent and Greenleft 6120 Electronic Safe Lock